Choose ozone output and controls for the treatment task

Professional ozone generators produce ozone for controlled treatment of enclosed spaces. Compare ozone output, airflow, timer and control functions together with room conditions and the required safety procedure. Ozone treatment must follow the operating instructions for the exact device, including restrictions on room access and post-treatment ventilation.

Use ozone generators for controlled professional treatment

Ozone is a highly reactive oxidising gas used in specialised professional treatment processes. It can react with selected odour-causing compounds and is used in applications such as restoration after fire or water damage where the exact appliance documentation supports the intended treatment.

An ozone generator is not a conventional occupied-room air cleaner. Select and operate the equipment according to its documented professional application and safety requirements.

Compare ozone output separately from airflow

Ozone output and airflow describe different characteristics of an ozone generator. Ozone output indicates the amount of ozone the appliance can generate over time, while airflow describes how much air the fan moves.

Compare both values for the exact model. A higher airflow value does not automatically mean higher ozone output, and a higher ozone output does not by itself determine the correct treatment time for a room.

Match the treatment to the room and contamination

Room volume is an important planning factor, but professional ozone treatment also depends on the type and intensity of the contamination, the affected materials, temperature and the required treatment objective.

Use the model-specific operating instructions when determining treatment duration. Do not transfer settings or treatment times from one Airozon® model to another.

Keep the treatment area inaccessible during ozonation

Ozone can be harmful when inhaled. During professional ozonation, follow the access restrictions specified for the selected device and ensure that unauthorised persons cannot enter the treatment area.

Where required by the operating instructions, remove people, animals and plants before starting the process and secure the room against unintended access.

Plan ventilation and controlled re-entry

The end of the generator's operating cycle does not automatically mean that the treated room is ready for normal use. Residual ozone must be allowed to decay or be reduced according to the documented procedure.

Follow the specified ventilation, ozone-concentration and re-entry requirements for the exact model before releasing the room for normal occupancy.

Consider materials and room conditions before treatment

Ozone is highly reactive and can affect certain materials. Check the device documentation and the materials present in the treatment area before starting an ozone process.

Room conditions also matter. Follow the specified requirements for moisture, temperature, placement and minimum clearances rather than assuming that an ozone generator is suitable for every enclosed environment.

Timers and controls support the treatment process

Depending on the model, Airozon® generators provide timers and adjustable ozone-output settings that help define a controlled treatment cycle. These functions can simplify professional operation and make the selected process easier to reproduce.

Automatic controls do not replace the safety procedure. Room access, ventilation and post-treatment checks must still follow the operating instructions.

Oxygen regeneration can shorten the post-treatment phase

Selected professional systems can be combined with equipment designed to accelerate ozone decomposition after room ozonation. This is a separate post-treatment function and should not be confused with ozone generation itself.

Check compatibility between the ozone generator and any ozone-regeneration equipment before planning a combined system.

Maintenance supports reliable ozone output

Professional ozone generators require inspection and maintenance according to their operating conditions and intensity of use. Air filters, electrodes and internal components must be kept in the condition specified by the manufacturer.

Follow the maintenance instructions for the exact model and do not assume that every generator uses the same electrode system, filter or service interval.

Check the complete treatment process before you choose

Select an ozone generator as part of a controlled professional treatment process rather than on ozone output alone.

  • Define the odour source, contamination and affected materials;
  • Compare ozone output, airflow and available control functions;
  • Check room conditions and the required treatment duration;
  • Follow all room-access, ozone-monitoring and ventilation requirements;
  • Verify maintenance and compatible post-treatment equipment for the exact model.